A Pump Quotation Says 20 GPM. Which Gallon Does It Mean?

Convert the original pump curve and purchase duty using the correct gallon. Confirm the same flow and head before approving the quote or acceptance sheet.

Suppose an importer asks for a submersible pump that can deliver 20 GPM at a specified head. The quote and the curve both show 20, but the buyer and supplier obtain different answers in litres per minute. First check whether GPM means US liquid gallons or Imperial gallons per minute. The two values do not describe the same volume. Establish a common flow unit for the curve, contract and acceptance sheet before comparing the pumps at the required head.

The unit can change the selection

A US liquid gallon is about 3.7854 L. An Imperial gallon is about 4.5461 L. In an illustrative comparison, 20 US GPM is about 75.7 L/min and 20 Imperial GPM is about 90.9 L/min. The second is about 20% greater. If the project needs 90.9 L/min and the purchase test asks for 75.7 L/min, the result addresses a different point on the curve. Maximum flow is not the delivery at a specified head. Compare candidates at the same flow and head.

Check the time unit separately. Packaging can list gallons per hour while a listing gives gallons per minute, which adds a factor of 60 to the conversion. If the head uses feet or metres, convert it against the same definition. For example, 20 US GPM at 10 ft means about 75.7 L/min at 3.05 m of total head. A single pressure at an unrelated tapping does not establish that head. Where pressure is given, check the liquid density, measurement positions and any elevation or velocity terms that apply. These figures do not represent a rating for any pump.

Trace the original axis before issuing converted values

Ask for the full curve showing the axes, units, version and model rather than a cropped marketplace picture. Confirm the gallon convention, whether flow is instantaneous or averaged, the head definition, water conditions, frequency and fitted accessories. Do not infer the unit from the destination market. A manufacturer or dealer can reuse a graph prepared for another market. If a source says only GPM and the supplier cannot confirm which gallon, keep the purchase duty open instead of making a silent assumption.

Put original and normalized values side by side, for example, 20 US gal/min (about 75.7 L/min) at 3.05 m total head. Use a second point to check the scale of the converted axis rather than converting only the maximum flow. Retain instrument units, conversion and rounding in the test sheet. Match the displayed precision to the measurement. A more elaborate conversion does not improve the accuracy of the original data. Use an approved version for the request, sample report, label, instructions and listing.

Resolve unit errors before disputing a sample

When numbers differ, compare the original axis and unit first. Then confirm the model, supply frequency, outlet accessories and test conditions before requesting a repeat at the relevant duty. If an approved document needs correction, record which conversion was wrong and what it did to the requested point. Identify affected quotes and packaging. A note saying the units changed does not show that the right pump was selected. If the agreement covers delivery with a hose or adapter, a correctly converted bare-pump curve still does not verify the package.

This comparison is for volumetric flow with a known test liquid. A consistent flow unit does not establish motor power, temperature rise or solids passage. Verify those separately where they affect the purchase.

Frequently asked questions

Is it safe to read GPM as US gallons every time?

No. Confirm whether the document means US or Imperial gallons and give the value in litres per minute as well.

Does 20 GPM written as 76 L/min prove the source is US?

It is close to a US conversion, but the source could have been converted incorrectly. Verify the original axis or lab report.

Which column should I use if both gallons are shown?

Use the unit named in the purchase duty, then compare a normalized flow and the same head. Equivalent points on the two scales should match.