YARDPUMP · Pump Guide

Does a Ribbed Discharge Hose Always Restrict a Submersible Pump?

Compare real bore, inner wall and pressure loss before choosing between ribbed hoses for the same submersible pump and route.

Suppose you are clearing rainwater from a garden and need a flexible discharge hose that reaches the far side of the yard. The supplier offers two hoses with the same nominal bore and a visible spiral on the outside. One is stiffer than the other. Which will deliver more water? Ask for a view of the actual inner wall and check the bore, fittings and pressure loss at the required flow. An external reinforcing helix can sit outside a smooth bore. Its appearance tells you very little about the resistance the water meets.

Identify the surface the water touches

The outside spiral may support the hose or help it keep its shape as it moves around an obstruction. Water travels past the internal surface. Deep internal ribs can change the effective flow passage and affect the loss along a run. A friction chart developed for smooth, round hose is a poor substitute when the internal shape is unknown. Even with two smooth bores, a smaller clear diameter or a narrow insert at either end can change the result. The connection size tells you what can attach. It does not tell you the clearance through the completed connection.

Mechanical fit matters just as much. A smooth hose pinched sharply at a step has lost the passage that made it attractive. A hose that holds its round shape on a tight route may deliver better despite looking less streamlined. Check the maker's permitted liquid, working pressure, temperature and bend limits for the intended service. Do not assume a suction hose can be used for discharge, or a discharge hose for suction. If a corner cannot be avoided, review its shape under the normal installed load rather than flattening the empty hose on the bench for a photograph.

Compare water delivered under repeatable conditions

Pick a safe test location where the selected pump, water and discharge are permitted. Use the same pump, comparable starting water level and outlet elevation. Set the length, supported route and end fittings as close to identical as the experiment allows. Changes in outlet position or a partly closed accessory can outweigh the wall difference. Support the hose so it does not pull the pump off its stable base. Wait until the hose fills and the flow settles before taking a timed volume. If startup delay matters, record it as a separate result.

For illustration, suppose hose A fills a twenty-litre vessel in forty seconds, and hose B takes sixty seconds over the same water level interval. The calculated delivery is thirty and twenty litres per minute respectively. Those figures show how to read the comparison; they are not representative losses for ribbed hose. If you used different adapters, the result describes two complete assemblies. Before attributing the difference to the inner wall, check actual bores, fittings, changes of elevation and the most restrictive bend. Repeat a small difference with the same timing and level marks. A difference around the uncertainty of the container and timer is too small to rank the hoses confidently.

Stop and isolate power from a dry location and release pressure as instructed before moving or changing fittings. Do not handle an energized pump or try to reshape a charged hose with your hands. If the installation cannot be tested safely, have a qualified person compare the route, pressure data and pump curve instead.

Buy for the planned route

Put the bore type, actual inside diameter, length, bend limits and supplied fittings on the request. When there is reliable pressure loss data at the intended flow, add the hose and fitting losses to the elevation and any outlet pressure requirement. Compare that working head with the pump curve. When a supplier cannot provide comparable data, a wet test of the exact kit can be more useful than another nominal diameter on the carton.

A temporary kit also needs a safe path, a supported outlet and a way to drain the hose after use. A permanent installation, an abrasive liquid and a hose that carries solids introduce other limits. Check the particular pump and hose before extending this comparison to any of those conditions. Choose the assembly that delivers the required flow on the route you can actually lay.

Frequently asked questions

Can I identify a ribbed bore in a product photograph?

Usually not from the outside. Ask for a section drawing or a clear view of the inside of an unconnected end.

Will increasing the nominal hose size guarantee more flow?

No. Check whether the adapters, loaded bends or working head still control the flow and whether the pump permits the new condition.

Can I use pressure loss data for another hose of the same nominal size?

Only if its actual bore, wall construction, liquid and flow conditions are relevant. Nominal size alone is insufficient.

Related reading